Home

Instron 3300 manual

  • Instron 3300 manual. 2742-205. The 5900 controller allows for the addition of digital I/O channels to connect The Instron® 3300 Series of mechanical testing systems provide simplicity, performance, and the highest level of quality needed for QC labs and production testing. Serial Number is on the right of column looking from the front, also on the back. 8800 Series Load Frame Accessories. ) Bluehill Universal is designed for touch interaction, thus it is recommended that a Windows 10 operating system with a touchscreen monitor be used for optimal user-experience. Secure one of the limit stops (either the upper or lower limit stop) to the limit switch rod. 5 in) of thread is exposed. Air Kits for Pneumatic Grips. If you expose more than 12 mm (0. 0 and 2. Rotate the spirit level 90 degrees to verify that the load frame is level side to side and front to back. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to confidently report the accuracy, Proper air ventilation is required to dissipate the heat generated from the frame base. Internet Protocol Version. These instructions describe the following table model dual column load frames, Model 5965 5 kN capacity, Model 5966 10 kN capacity, Model 5967 30 kN capacity, Model 5969 50 kN capacity. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to confidently report the accuracy, repeatability, and Instron Product Guides and Manuals. The all-new 3400 and 6800 Series are successors to Instron’s popular 3300 and 5900 Series systems and are available in single and dual column models, with capacities ranging from 500 N to 50 kN 3340 Series. com Page 36 Chapter: Installation 4. Installation of the 2603-080 or 2603-085 Onto 3300, 4200, 4400, 5500 5800 and 5900 Series Two Column Machines. The design, manufacture, and performance verification is conducted with materials testing applications in mind. Designed for all users from novice to expert, it utilizes quick and straightforward operation without compromising the flexibility required for advanced applications. 500Hz data acquisition rate ( Bluehill ® Universal) Chapter 1. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to No longer in production, the 3300 Series universal testing systems were replaced by the 3400 Series testing systems in 2020. 15. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to Serial Number is on the back of frame. Designed to perform tensile, compression, flex, peel, puncture, friction Purpose. 5, 1. Select . Instron Connect includes a number of technologies that create a secure connection between the testing systems at your facility and Instron. Instron’s newest 5900 series electronics, with Operator Dashboard and new Bluehill Universal software, are installed on the existing Instron test frame. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to 4. The load cells incorporate overload protection and can withstand loads up to 150% of their force capacity without damage and 300% without Instron Connect offers the highest level of technical support for Instron systems around the world. 2810-400 Flexure Fixture. 6. Loop Tension at specified Elongation and Elongation at Specified Loop Tension are test procedures that require 3 cycles to Page 35 2. com. Our grips range in force from one gram to 2 meganewtons and can accommodate a diverse range of materials such as thread, rope, elastomers, plastic, composites, metals, and more. These instructions describe the following table model dual column load frames, Model 3365 5 kN capacity, Model 3366 10 kN capacity, Model 3367 30 kN capacity, Model 3369 50 kN capacity. Machine base adapters are generally used for connecting a grip or fixture to the machine. Ensure that the system is on and the crosshead is stationary. The fixture mounts onto Instron’s electromechanical testing machines. For those with unique applications, our custom engineering group will Chapter 1. ±1% of reading from 1/200 to 1/500 of the load cell capacity. This test is performed with various types or combination of materials, and tested at a constant-rate-of-extension. Pneumatic air kits, foot-switches, or distribution kits are optionally provided for ease of grip closure and productivity. 2 KB. This service ensures that testing parameters are being met and that associated results are being calculated accurately. 500Hz data acquisition rate ( Bluehill ® Universal) Mini Environmental Chambers for Instron Single Column 3300, 5500, and 5900 ETS Model 5502 Operating Manual . Tensile testing is a fundamental type of mechanical testing performed by engineers and materials scientists in manufacturing and research facilities all over the world. Also for: 34sc-05, 34sc-1, 34sc-2, 34sc-5. 5. Contact Us For Details. Page 9: Chapter 1 Introduction ® This manual documents the following Instron Long Travel Extensometer catalog numbers: • 2603-080 - 250 mm travel - for Instron twin column electromechanical testing machines. 2501-113. Building on a 74 year legacy of excellence in mechanical testing, Instron is proud to announce the latest generation of universal testing systems. Instron manufactures tensile, compression, fatigue, impact, rheology, and structural testing machines, testing a variety of materials and range of applications. The 3340 single column, 3360 dual column table models, and 3380 floor models were first introduced in 2002 and were designed to perform tensile, compression Torsion Add-On 3. Position the voltage selector card so that the indicator pin points up, as shown in. View and Download Instron 3400 Series operator's manual online. 2742-315. Features. More Info. ElectroPuls™ and 8800 dynamic systems can also take advantage of Bluehill Universal’s versatility and ease-of-use when running static tests. Rigid mechanical design ensures the best possible conditions for repeatable tests and reliable results. 3300, 5500 and 5900 Machines with 2603-080 or 2603-084 . Firmly hold the yellow part of the limit stop to gently move the stop either downward (in compression) or upward (in tension) about 3 mm (1/8 in). 3300 Dual column. Service and Support. 2603-086 - The calibration bar supplied provides gauge length settings of 10, 20, 25, 50 and 100 mm, and 0. It can also be used with either fully-automated or manual testing systems. Instron® offers a wide variety of tensile grips to suit your industry and testing application. Table requirements. Single Column Table. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to confidently The 2519-xxxN Series load cells are specifically designed for use with 3400 and 3300 single column testing systems. Message 2969 TENSILE TESTING. Instron’s 90° Peel Test Fixture (Model 2820-035) and the Variable Angle Peel Test Fixture (Model 2820-036) are testing devices designed to measure the force required to peel a sample from its backing material or substrate. 2742-205 ±3 kN, ±25 Nm Pneumatic Fatigue Grips. The 3400 Series universal testing machines range in capacity from 500 N to 300 kN and are designed to meet all of your force testing needs. 2742-103. From electromechanical systems used to test high-strength metals and The Instron® 3300 Series of mechanical testing systems provide simplicity, performance, and the highest level of quality needed for QC labs and production testing. 5 in) of thread, there is a risk that the threaded adapter can separate from the foot. Torsion Add-On 3. If you are unsure which network connection is for the Instron system, unplug the Ethernet cable from the EFI adaptor (3300/5500) or from the Instron itself (5500A/5900) and you should see a red “X” over the connection that the Instron is plugged into. 2580 Series Static Load Cells. The 3340 single column, 3360 dual column table models, and 3380 floor models were first introduced in 2002 and were designed to perform tensile, compression, flexure/bend, peel, tear, shear, and cyclic tests. All 5900 Series systems are designed to provide high stiffness and precise alignment for testing everything from medical devices to high-strength composites. Assemble the mounting screw and appropriate washer, as shown in the figure. Electropuls All-Electric Dynamic Test Systems. 3300 Single Column. Remove the fuse holder from the power input connector, as shown in Figure 4-4. 68TM-50 Packaging dimensions and weight. instron. 1. USB adapters may be used. It is true that the 3300 series is affordable compared to the more expensive 5900 Series. 34TM-50 Packaging dimensions and weight. 4 and click . 4 MB. 2210-860. 5% of reading down to 1/200 of load cell capacity. Instron Connect Product Life Cycle Service Success Stories. A tensile test (or tension test) applies force to a material specimen in order to measure the material's response to tensile (or pulling) stress. iii. Tensile grips for composites and metal that provides accurate and repeatable specimen alignment capable of meeting the alignment requirements of Nadcap AC7122-1 and AC7101. Single Column Table Top Models. 4. 5 N to 600 kN, static load cells are suitable for a variety of testing applications including tension, compression, cyclic, and reverse stress tests. The Wilson VH3300 offers an advanced, fully automated hardness tester for fulfilling both Vickers and Knoop hardness testing requirements. 3342. The supporting table must be at least 762 mm (30 in) high. www. 1 unused Ethernet port (Instron® 3300/5500/5900/3400/6800 only - 2 Ethernet ports if network accessibility is required. 2716-028 and 2716-030. 3340 Series. Designed for exceptional performance, the 6800 Series delivers unparalleled accuracy and reliability, improved Carefully read all relevant manuals an d observe all Warnings and Cautions. Nov 2, 2018 · Instron 3300 Series universal test machines have also evolved to become positioned as the Instron product line of 'most affordable' test machines. Insert a small flat-head screwdriver into the middle of the connector and pry out the fuse holder (1), as shown below. Instron pneumatic wedge action grips may be used in static or dynamic materials testing applications, interchangeable wedge-shape grip faces accommodating 3340 Series. 0 inch. On machines 10 kN and below, a clevis adapter with a through hole for a screw is used. Instron® load cells are an integral part of a materials testing system. Instron products, to the best of its know ledge, comply with various national and The 5900 Series frames remain compatible with our extensive selection of accessories, including grips, fixtures, load cells, extensometers, environmental chambers, torsion add-on, automated XY stage, auto-injector testing system, and many other frame accessories. Fatigue, Tensile, Compression, Instron 2. electrotechsytems. 25 KIP 3000 PSI Hydrostatic. Instron® high force universal testing machines perform tensile, compression, bend, peel, tear, and other mechanical tests on materials and products to ASTM, ISO, and other industry standards. Communication Errors with Bluehill Universal, Bluehill 3 or Bluehill 2 on Instron 3300, 5500, 5500A and 5900 Systems. 2150. When not in use, the mounting allows you to quickly position the extensometer out of Controller. About the Extensometers. Products 3/8/2021 493. Load cells for Instron’s 3300, 3400, 5900, and 6800 Series universal testing Insert a small flat-head screwdriver into the middle of the connector and pry out the fuse holder, as shown in Figure 4-3. Examples are the 3300, 4400, 5500, 5800 and 8800 controllers. Learn More. ±0. The term Caution is used where a hazard may lead to damage to equipment or to loss of data. Catalog no. 3360 Series. 2210-869. Ranging in capacity from 2. 5500. Cat #. These instructions assume the following: View & download of more than 134 Instron PDF user manuals, service manuals, operating guides. Also for: 34tm-5, 34tm-10, 34tm-30, 34tm-50. Instron’s Bluehill 3 software was released in 2010 and moved out of production and into Phase 2 in 2017 when Bluehill Universal was introduced. Different controllers have different testing capabilities. Machine Base Adapters. Bluehill 3 or Bluehill 2 on Instron 3300, 5500, 5500A and 5900 Systems. To ensure stability, the spacing of the table legs should be a minimum of 762 mm (30 in) wide and 762 mm (30 in) deep. 2210-862. Product Support: www. The Instron® 3300 Series of mechanical testing systems provide simplicity, performance, and the highest level of quality needed for QC labs and production testing. Test Equipment, Power Tool user manuals, operating guides & specifications Refer to “68FM-300 Page 36 When the testing site is ready, and the frame has been moved to its final operating ® location, contact Instron to schedule an installation appointment. 0 easily mounts to any new or existing Instron 6800 or 5900 system, adding torsion capability to your lab while saving valuable lab space. Download. Services 10/16/2023 1. Superior Stiffness and Alignment. Locate the lower knife edge in the lower gauge length notch in the calibration bar. For low force applications, the 3400 Series single columns provide For We have 2 Instron 300DX manuals available for free PDF download: Operating Instructions Manual, System Concepts Manual Instron 300DX Operating Instructions Manual (96 pages) Static Hydraulic Universal Testing System This manual is also suitable for: 34tm-5 34tm-10 34tm-30 34tm-50. Properties. Catalog nos. Load cells for Instron’s 3300, 3400, 5900, and 6800 Series universal testing 3360 Series. compatible with 3300, 3400, 5500, 5900, and 6800 electromechanical dual column systems, as well as LX, DX, HDX, and KPX static hydraulic testing systems (Bluehill® required). Application Based Testing Solutions. 16. 2. Designed for use with electromechanical testing instuments, long-travel extensometers can be used to measure specimen elongations up to 30 in or 750 mm. The design, manufacture, and performance verification is conducted with materials testing applications in mind and the cells are certified in accordance with It can also be added to existing 6800, 3400, 5900, 3300, 5500, 59R, and IS02 static testing systems, in addition to systems upgraded to 5900 and 6800 electronics. Instron’s patent-pending Operator Protect system architecture makes the 3400 Series simpler, smarter, and safer than ever before. Sitemap. Expansion Channel Module. Use the information in Table 13 on page 58 to verify that: the packaged frame fits through all doorways and hallways leading to the final location. Dual Column Table Model. 3 in) vertical test space. Proper air ventilation is required to dissipate the heat generated from the frame base. As you make adjustments, make sure that no more than 12 mm (0. Existing load cells and accessories Accessories, attachments, and upgrades are designed for Instron 3300, 3400, 5900, and 6800 Series test systems. Precision Mechanical Wedge Grips. Our problem-solving tools harness innovative technology to rapidly troubleshoot issues and answer your technical questions, increasing productivity, reducing risk and minimizing downtime. Set the IP address to Manuals. On 30 kN, 50 kN, and 100 kN machines, a flange adapter with clevis and bolt circle is used. The fixture sled is designed with Instron static load cells are designed for use with our 6800, 3400, 5900, and 3300 Series testing systems. Back; Home; Products. Generate standardized files containing user-defined tables or lists of method parameters, test results and/or raw data. Instron Model 8502 Two Column Material Fatigue Testing System Hydraulic Lifts with 15. iv. The term Warning is used where a hazard may lead to injury or death. Instron also offers a 5900 upgrade program designed to extend product life and improve productivity with minimal cost and downtime. After 4+ years of limited support, Bluehill 3 will be discontinued. Instron static load cells are designed for use with our 6800, 3400, 5900, and 3300 Series testing systems. 3400 Series test equipment pdf manual download. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to confidently This manual is also suitable for: View and Download Instron 3400 Series operator's manual online. 100 kN and 250 kN Force Capacities. The Expansion Channel Module allows 6800 and 5900 Series Electromechanical Testing Systems users to add up to eight channels of signal conditioning and control. 6800 Series. In the United States and Canada, you can call 1-800-473-7838. Telephone: +1 800 877 6674 Back The long-travel (XL) extensometer is a precise device for measuring strain in highly extensible materials. The controller is the piece of hardware that controls the testing frame and any ancillary equipment in your testing system. Place the load cell against the bottom of the crosshead, ensuring that the anti-rotation pin fits securely in place against both the crosshead and load cell. 100 kN (22,500 lbf) capacity. Manuals. The XL is designed to clamp directly onto a specimen quickly and easily. Page 8 5800 Controller . Serial Number is on the back of frame. Installation of the 2603-080 or 2603-085 Onto 4501 and 4502 Two Column Machines. Compatible with hundreds of accessories for a wide range of applications, these universal testing systems are available in a multiple sizes and configurations for R&D, QC, and other mechanical testing up to 300 kN force. Bring the carriages together until they just touch. These systems are available in a range of sizes and maximum force capacities. Instron recommends leaving the load frame in its packaging while moving it to its final site location within your building. Fabric Loop Grips are used for tension and elongation testing of wide or narrow elastic fabrics. Air cushion isolators and Hydraulic grip The 3400 Series Universal Testing Machines range in capacity from 500 N to 300 kN and are designed to meet all of your force testing needs. Careers Subscribe to Our Newsletters. As you know, Instron equipment is built to last, and Bluehill 3 has become an integral tool for your lab’s productivity. Maximum speed 508 mm/min (20 in/min) 1430 mm (56. Load cells for Instron’s 3300, 3400, 5900, and 6800 Series universal testing systems. 18. Loadframe accessories for Electropuls systems include a high stiffness support table and safety guards. When the machine is level, use the 16mm thin open-ended wrench to hold the level adjuster nut (2) while using the 19mm wrench to tighten the lock nut (1) on each foot. Remove the fuse holder (1) from the power input connector, exposing the voltage selector card (2) as shown below. 2742-103 ±1 kN Pneumatic Fatigue Grips. 5 kN to 5 kN, 112 lbf to 1125 lbf. Figure 4-5. Serial Number is on the top of base near rear middle. 3300. TestResources manufactures a wide selection of standard electromechanical test machines with over 500 test . Mar 30, 2017 · Make it easier for your lab to develop unique report output files, which can be seamlessly imported to a Lab Information Management System (LIMS) or other reporting application, with specialized export settings. Jun 13, 2011 · The first in a series of how-to videos, this Instron Bluehill 3 tutorial walks the user through steps of getting started with the latest materials testing so As you make adjustments, make sure that no more than 12 mm (0. com 833-ENV-GURU (833) 368-4878 Instron is a leading provider in calibrating Pendulum Impact Testers and is an active participant in the development of ISO 13082-99 and ASTM D256-2010 standards. Installation of the 2603-080 or 2603-085 Onto 4300 Series Two Column Machines. Dual Column Tabletop Models. 2717-080. • 2603-084 - 250 mm travel - for Instron Features. . Built for Durability. Automatic transducer recognition and electrical calibration makes them easy to use. They are intended to get you started working with your testing system. Designed for exceptional performance, the 6800 Series delivers unparalleled accuracy and reliability, improved Service and Support. 2742-315 ±10 kN ±100 Nm Pneumatic Fatigue Grips. 3300 Single Column Testing Systems for load capacity. Serial Number Locator. Dynamic Fatigue Rated 5. Tighten the mounting screw by hand so that it secures to the load cell underneath the crosshead. 5900, 5500A. It utilizes Bluehill Universal’s dedicated axial-torsion and method types in a user-friendly and intuitive interface. Our attention to every element of the system is what separates Instron from other testing equipment suppliers and allows us to confidently report the accuracy, Instron Connect includes a number of technologies that create a secure connection between the testing systems at your facility and Instron. No longer in production, the 3300 Series universal testing systems were replaced by the 3400 Series testing systems in 2020. Materials Testing. These instructions assume the following: Manuals. Serial Number is behind motor near back right. Dec 15, 2017 · As many fatigue tester load frames are designed to last and provide many years. 2530 Series Load cells with capacities of 500 N to 300 kN are for use with 3400 and 3300 testing systems. Services These accessories, attachments, and upgrades are designed for Instron 3300, 3400, 5900 and 6800 Series test systems. Refer to the load cell installation drawing and collect together the correct mounting screw, washer, anti-rotation pin and locating ri ng for your combination of load frame and load cell. Item Name. Our Company. The 2630-100 series extensometers convert the mechanical displacement of a strained test specimen into an electrical signal. 3. Mount the calibration bar in the lower grip only. Instron 8502 Manual. 04. When used with the current range of Instron testing machines, each extensometer is automatically recognised, and can be calibrated at the touch of a button. Our problem-solving tools harness innovative technology to rapidly troubleshoot issues and answer your The 3400 Series Universal Testing Machines range in capacity from 500 N to 50 kN and are designed to meet all of your force testing needs. Out of Production 3300 Series Universal Testing Systems. The 2519 Series load cells are specifically designed for use with Instron’s 3300 Single column testing systems. 2530 Series load cells with capacities of 5 N to 100 N are for use with 6800, 3400, 5900, and 3300 Series testing systems. Hydraulic Grip Pump. ® A list of Instron offices is available on our website at www. cj il qe hz cw wv at ni gr nh